video
Hemodialyzer Machine

Hemodialyzer Machine

• All treatment modes can adopt the Citrate anti-coagulation.
• Seperate citrate infusion pump and weighing scale.
• Control the citrate flow accurately. Automatic injection by proportion, achieve the safe topical citrate anticoagulation.

Product Introduction
Full Range Of Blood Purification Equipments

 

SWS-5000B

Blood Purification Equipment

SWS-5000

Professional Blood Purification Equipment

SWS-5000

Full Functionl Blood Purification Equipment

SWS-5000A

Blood Purification Equipment

Clinical advantages of citrate anticoagulation:

• All treatment modes can adopt the Citrate anti-coagulation.

• Seperate citrate infusion pump and weighing scale.

• Control the citrate flow accurately. Automatic injection by proportion, achieve the safe topical citrate anticoagulation.

Advantage of double input channel for substitution fluid flow:

• Avoid Calcium ion precipitation, ensure the treatment result.

• Automatic injection by proportion, achieve the safety supplement of the substitution fluid.

• Exte r nal infusio n pump is not required, easy operation and safe treatment.

Flexibility

 

Convenient one-button prime

One button mode switch and one button prime, more convenient for clinical treatment.

01

Multiple dilution modes of substitution fluid

Adopt various methods for substitution fluid such as the pre-dilution, post- dilution, pre -post mix dilution. One button switch dilution method, do not need to change the connection of tubing manually.
Can set the flow of pre-post-dilution substitution fluid.

02

Multi-functional infusion pump

The multi-functional infusion pump can be used for bolus injection of heparin, calcium chloride and ect. and recognize the syringe size automatically, such as 10ml, 20ml, 30ml and 50ml.

03

Safety Movement

Small blind field of vision to ensure safety of equipment movement.
Parts failure for 120KM movement test.

04

Guide for tubing installation

Easy operation for tubing installation, the system will guide installation with pictures and text.

05

Ergonomic design, make the machines serve people

Rotatable big touch screen operation system, to observe and operate from different angles, to meet the requirement for rapid response under different scenarios.

06

Reliable fluid change management of substitution fluid and waste fluid

The maximum range of weighing scale is 30kg, and can hang different fluid bags with higher accuracy of fluid meter, which can decrease the workload of medical care.
Unique design for foolproof fluid change, easy operation, high safety.

07

 

Precise

 

The temperature of substitution fluid flow can be detected, the temperature control is more accurate.


The liquid temperature is detected and feedback control precisely
• Unique substitution fluid flow temperature monitor and feedback system.
• Adopt infrared monitor to detect the temperature, the accuracy can be ±1.
• Adopt double-side heating device which can support large flow heating.

 

Precise control of fluid balance

• The scale system accuracy can be ±5g.

• The fluid balance error can not be more than ±20mL/h, the Cumulative error can not be more than±100mL.

• Satisfy the clinical requirement for the fluid accuracy (1mL/min~250mL/min).

 

More Accurate Liquid Flow
• Five high-precision peristaltic pumps.
• Wide flow range for meet more clinical needs.
• Stable operation and more comfortable treatment.


Reliable parts
• Motors, weighing sensors and pressure sensors have been purchased globally, ensure the quality of the products.
• The peristaltic pump is executed according to the strict quality standards and have been passed the trouble-free test of continuous operation for 90 million revolutions.
 

Comprehensive Treatment Mode


SWS-5000 has fourteen blood purification treatment modes and it's the most comprehensive functional device in the market, it can perform the contnuous blood purification therapy (CBP), plasma adsorption therapy, albumin adsorption therapy and hemoperfusion to meet various clinical treatment needs.

CVVHDF (Continuous Venous Venous Hemodiafiltration)

Substitution fluid double channel input
Clinical application:
Severe Acute Kidney Injury (Aki), instability and continuously remove excess water or toxic substances, such as AKI with severe electrolyte imbalance, acid-base metabolic imbalance, heart failure, pulmonary edema, brain edema, acute respiratory distress syndrome (ARDS), severe infection after postoperative surgery, etc.
Chronic renal failure (CRF), combined with acute pulmonary edema, uremia encephalopathy, heart failure, hemodynamic instability, etc.

CVVH (Continuous Venovenous Hemofiltration)

Front and back end simultaneously dilution and exchange fluid dual-channel input
Clinical application:
Seve re Acute Kidney Injury (Aki), instability and continuously remove excess water or toxic substances, such as AKI with severe electrolyte imbalance, acid-base metabolic imbalance, heart failure, pulmonary edema, brain edema , acute respiratory distress syndrome (ARDS), severe infection after postoperative surgery, etc.
Chronic renal failure (CRF), combined with acute pulmonary edema, uremia encephalopathy, heart failure, hemodynamic instability, etc.

CVVHD (Continuous Venous Hemodialysis)

Exchange Fluid Dual-Channel Input
Clinical application:
Severe Acute Kidney Injury (Aki), instability and continuously remove excess water or toxic substances, such as AKI with severe electrolyte imbalance, acid-base metabolic imbalance, heart failure, pulmonary edema, brain edema, acute respiratory distress syndrome (ARDS), severe infection after postoperative surgery, etc.
Chronic renal failure (CRF ), combined with acute pulmonary edema, uremia encephalopathy, heart failure, hemodynamic instability, etc.

SCUF (Slow Continuous Ultrafiltration)

Clinical application:
Caused by various resons of poor effects on drug treatment Severe edema
Refractory heart failure
Acute and chronic pulmonary edema

HP (Hemopurfusion)

Clinical application:
Acute drug poisoning or other toxicosis.
Uremia, especially refractory itching , refractory hypertension.
Severe hepatitis, especially hepatic encephalopathy caused by fulminant hepatic failure, hyperbilirubinemia, sepsis or systemic inflammation syndrome.
Psoriasis or other autoimmune diseases.
Other diseases such as schizophrenia, thyroid crisis, tumor chemotherapy, etc.

CPFA (Continuous Plasmafiltration Adsorption)

Clinical application:
It is mainly used to remove medium and macromolecular toxins such as inflammatory mediators and cytokines.

DFPP (Double Filtration Plasmapheresis)

Clinical Application:
Clinical Application: Rheumatic Immune Disease
Immun Nervous System Disease
Digestive System Disease Hematological Disease
Renal Disease
Rejection After Organ Transplantation
Autoimmune Skin Disease Hypercholesterolemia
Hyperlipoproteinemia Drug poisoning, etc.

PE (Plasma Exchange)

Clinical Application:
Clinical Application: Rheumatic Immune Disease
Immun Nervous System Disease
Digestive System Disease Hematological Disease
Renal Disease
Rejection After Organ Transplantation Autoimmune Skin Disease
Metabolic Disease Drug Poisoning, Etc.

MARS (Molecular Adsorbent Recirculating System)

Clinical application:
Hyperbilirubinemia (such as siltation / refractory itching) Acute exacerbation of chronic liver disease, acute / f ulm inant hepatic failure.

PDF (Plasma Diafiltration)

Clinical application:
Abiotic artificial liver blood purification treatment, suitable for patients with liver failure and renal failure, electrolyte imbalance.

PA (Plasma Adsorption)

Clinical application:
Immune system disease of kidney and rheumatism nervous system disease hematological Disease hepatic failure graft-versus-host disease severe drug or toxin poisoning other diseases: DCM (dilated cardiomyopathy), β2-microglobulin

FPSA (Fractionated Plasma Separation Adsorption System)

Clinical application:
Hyperbilirubinemia (such as siltation / refractory itching) Acute exacerbation of chronic liver disease, acute / fulminant hepatic failure.

SPAD (Single-Pass Albumin Dialysis)

Clinical application:
Hyperbilirubinemia (such as siltation / refractory itching) Acute exacerbation of chronic liver disease, acute / fulminant hepatic failure.

RAD (Repeated Albumin Dialysis)

Clinical application:
Hyperbilirubinemia (such as siltation / refractory itching) Acute exacerbation of chronic liver disease, acute / fulminant hepatic failure.

Basic Information

 

Dimension Height

1720 mm

Width

635 mm

Thickness

578 mm

Weight

About 75Kg

Electrical Parameters

Voltage

~110/220V

Frequency

50/60Hz

Power

500VA

Backup Battery Capacity

2×12V/4Ah

 

Pressure Monitoring

 

Venous Pressure Monitoring (Vp)

-500mmHg ~ +700mmHg

Accuracy: ±5mmHg

Arterial Pressure Monitoring(Ap)

-500mmHg ~ +700mmHg

Accuracy: ±5mmHg

Transmembrane Pressure Monitoring (Tmp)

-500mmHg ~ +700mmHg

Accuracy: ±5mmHg

Primary Membrane External Pressure Monitoring (Pm1)

-500mmHg ~ +700mmHg

Accuracy: ±5mmHg

Secondary Membrane Pressure Monitoring (Pm2)

-500mmHg ~ +700mmHg

Accuracy: ±5mmHg

 

Flow Monitoring

 

Blood pump flow (BP)

0mL/min, 30mL/min ~ 600mL/min

Accuracy: set value ±10%

LP1

0mL/min, 1mL/min ~ 250mL/min
Accuracy: ±0.1mL/min or ±5% of set value

Waste Liquid Pump Flow (UFP)

0mL/min, 1mL/min ~ 250mL/min
Accuracy: ±0.1mL/min or ±5% of set value

LP2

0mL/min, 1mL/min ~ 250mL/min
Accuracy: ±0.1mL/min or ±5% of set value

Function Pump Flow (FP)

0mL/min, 1mL/min ~ 250mL/min
Accuracy: ±0.1mL/min or ±5% of set value

Infusion pump flow

 

Flow Adjustable Range

0mL/h ~ 10 mL/h

Error Range

±0.2mL/h or ±5%

Rapid Injection Flow

10mL/h ~ 2000mL/h

Syringe Specification

10mL / 20mL / 30mL / 50mL

Dehydration Error

≤ ±20mL/h

Liquid Balance Control

≤ 100mL

 

Liquid Balance Control

 

Scale Number

4

Rehydration Scale

0kg ~ 30kg

Accuracy: ±5g or ±0.1%

Waste Liquid Scale

0kg ~ 30kg

Accuracy: ±5g or ±0.1%

Auxiliary Rehydration Scale

0kg ~ 12kg

Accuracy: ±5g or ±0.1%

Auxiliary Rehydration Scale

0kg ~ 12kg

Accuracy: ±5g or ±0.1%

 

Substitution fluid flow temperature control

 

Control Range

33℃~ 40℃

Accuracy

Control error ±1°C

 

Safety Monitoring

 

Blood Leakage Monitoring ≤ 0.35mL/min (HCT 32%)
Air Monitoring >0.02mL bubbles

Note: The above parameters are SWS-5000 se ries, Specific paramete rs are subject to the operating manual.

 

Each Model Treatment Mode Contrast

 

Treatment Mode

SWS-5000 (full function)

SWS-5000 (professional)

SWS-5000A

SWS-5000B

Citriate anticoagulation

Substitution Fluid Double Channel Input

CVVH - Continuous Veno-Venous Hemofiltration

CVVHD - Continuous Veno-Venous Hemodialysis

CVVHDF - Continuous Veno-Venous Hemodiafiltration

SCUF -Slow Continuous Ultrafiltration

HP - Hemoperfusion

PE - Plasma Exchange

PA - Plasma Adsorption

CPFA - Continuous Plasma Filtration And Adsorption

FPSA - Fractional Plasma Separation And Absorption

MARS - Molecular Absorbent Recycling System

SPAD - Single Pass Albumin Dialysis

DFPP - Double Filtration Plasmapheresis

RAD - Repeated Pass Albumin Dialysis

PDF - Plasmadiafiltration

 

Hot Tags: hemodialyzer machine, China hemodialyzer machine manufacturers, suppliers, factory, Hemodialysis Equipment Disinfectant, RO Water Plant for Hemodialysis, Single Use Dialyzer, Safety Fistula Needle, 15g Dialysis Needle, Heparin Sodium 5000

Send Inquiry

whatsapp

Phone

E-mail

Inquiry

Bag