Hemodialysis Water Treatment System

Your Professional Hemodialysis Water Treatment System Supplier

 

 

Our goal is to become your true partner in the field of aerosol chamber in China. DSX International Limited provide comprehensive medical solutions. The factory has accumulated rich manufacturing experience. Our company is committed to applying advanced manufacturing technology and strict quality control standards to every product. The price is competitive and the product is quality-assured, which is a good choice for your long-term cooperation.

 

 
 
Why Choose Us
 

Our Certifications: Most of our products have obtained CE, ISO, or FDA certifications.

 

Our Services: Our company has a professional sales team to provide you with high-quality pre-sales consultation services. During the order production process, customers can communicate with us at any time to understand the production progress, and we provide high-quality after-sales service.

 

Customized Solutions: We are committed to providing comprehensive medical solutions to meet the diverse needs of our clients.

 

Quality Control: All our sales and production are strictly carried out in accordance with ISO9001 and ISO13485 standards and requirements.

 

Advantages of Hemodialysis Water Treatment System

Patient safety

Hemodialysis water treatment ensures the safety of patients undergoing dialysis by providing water that meets strict purity standards. High-quality water minimizes the risk of infection, inflammation, and adverse reactions during hemodialysis treatment, improving patient outcomes and quality of life.

Treatment efficacy

High-purity water is essential for effective hemodialysis water treatment, as it prevents the introduction of contaminants and toxins into the patient's bloodstream. Proper water treatment ensures that the dialyzer functions optimally, allowing for efficient removal of waste products, excess fluids, and electrolytes from the blood.

Reduced complications

Hemodialysis water treatment reduces the risk of complications such as dialysis-related infections, allergic reactions, and adverse events associated with exposure to impurities and contaminants in the water. By providing clean and pure water, treatment-related complications are minimized, resulting in safer and more effective hemodialysis therapy.

 

Specification of Hemodialysis Water Treatment System

 

Name

RO pure water treatment machine for dialysis

Water capacity

500L/H

Rated voltage

AC 380V/400V/415V/240V, 50/60Hz; 3-Phase 4-wire (depends on clients' detail situation)

Desalination rate

99.8%

Recovery rate

65%-85%

Ion removal rate

99.5%

Bacteria & endotoxin remove rate

99.8%

Working temperature

5-40°C

Tech adopted

Pretreatment + RO system

Pre-treatment

Sand filter, Active carbon filter, Water softener

Control

PLC control system adopted

 

Features of Hemodialysis Water Treatment System

 
 
01
 

large enterprise scale

High purity requirements: Hemodialysis water must meet stringent purity standards to prevent complications and ensure patient safety. Contaminants such as bacteria, endotoxins, chemical impurities, and dialysis-specific substances must be effectively removed or reduced to levels that are safe for patient exposure.

 
02
 

Standardized Production

Specialized filtration: Hemodialysis water treatment systems utilize specialized filtration technologies, including reverse osmosis (ro), Ultrafiltration (uf), carbon adsorption, and deionization, to achieve the required water quality standards. These technologies remove impurities, particles, and dissolved substances from the water, ensuring that it meets the stringent requirements for hemodialysis.

 
03
 

High-Quality Customized Services

Continuous monitoring: Continuous monitoring of water quality parameters, including conductivity, total dissolved solids (tds), bacterial endotoxin levels, and microbiological contamination, is essential to ensure the safety and efficacy of hemodialysis treatment.

Dialysis RO Water Treatment Machine

 

Components of Hemodialysis Water Treatment System

 
 

Booster pump: Provide power for pretreatment & ro system. Boosters pump in the whole system has high quality and long service life.

 
 

Sand filter: Different size of quartz sand will be put in the sand filter. Get rid of turbidity, suspended matter, organic matter, colloid, etc. In the water.

 
 

Active carbon filter: Remove color, free chloride, organic matter, harmful matter, etc. Remove 99% of the chlorine and organic chemicals. Provide enhanced reduction of taste, odor, and color. Protect and prolong the life of ro seawater desalination membrane.

 
 

Water softener: Soft and reduce the hardness of water, make it healthy for dialysis.

 
 

Pp filter: Prevent any deposition of large particles, for holding back any large particulates such as iron, dust, ss matter, impurity into the ro membrane.

 
 

High pressure pump: Provide power for ro system, equipped with over-heat, protect and pressure controller.

 
 

Ro system: Adopts high desalination rate membrane to treat water and get clean water for human consumption. It removes the following water contaminants that May be present in water: Lead, cooper, barium, chromium, mercury, sodium, cadmium, fluoride, nitrite, nitrate, and selenium.

 
 

Electrical control system: All pipeline & fittings adopted in the whole plant are anti-corrosion material.

 

 

Other Service of Hemodialysis Water Treatment System

 

Packing

Box

Delivery

By air, by sea, by express. Sample and products in small quantity can be delivered by DHL, Fedex,TNT,UPS.

Payment terms

We can accept TT, LC at sight, paypal etc. For small quantity orders, it will be 100% TT advance payment.

 

FAQ

 

Q: What is the role of RO water in dialysis?

A: Dialysis machines need ultra pure water to prevent patients from getting infections from micro-organisms in the water.

Q: What is the normal range of TDS in dialysis RO water?

A: The following are examples of typical dialysis water quality standards: TDS: Less than 200 mg/L (milligrams per liter). Bacteria Levels: Zero detectable bacteria per milliliter. Endotoxin Levels: Less than 0.25 EU/mL (endotoxin units per milliliter).

Q: How to test dialysis water?

A: There are several methods to test for endotoxins when dialysis water testing. The main methods used for bacterial endotoxin testing (BET) use Limulus amoebocyte lysate (LAL) and are gel-clot, kinetic chromogenic, and kinetic turbidimetric.

Q: What is the temperature of dialysis water?

A: For example, reverse osmosis systems operate most efficiently (produce the largest volume of dialysis-quality water for the number and type of membranes) at a feed water temperature of 77°F. This is accomplished through the use of a water heater in conjunction with a temperature blending valve.

Q: What removes chlorine and chloramines in dialysis?

A: Activated carbons can remove contaminants like chlorine and chloramine that can be harmful to the patient from the water used for dialysis.

We're well-known as one of the leading hemodialysis water treatment system manufacturers and suppliers in China. If you're going to wholesale high quality hemodialysis water treatment system, welcome to get more information from our factory. Also, custom service is available.

RO Plant for Hemodialysis, Dialysis RO Water Treatment Machine, hemodialysis water treatment system

whatsapp

Phone

E-mail

Inquiry

Bag